MRT 6-30

Electric boiler with three-stage control 6-30 MRT

Three-stage control make proportionately control of the water temperature in the water container according to the difference between the set temperature and the current temperature in the heating place.
Manufactured models MRT: – 6kW, 8kW, 10kW, 12kW, 15kW, 22kW, 30kW. Models up to 12kW electric boilers can be powered single-phase and three-phase. All other boilers are supplied with three-phase voltage.
PRODUCT DATAMRТ 6-30KW
UNITMRT 6MRT 8MRT 10MRT 12MRT 15MRT 18MRT 22MRT 24MRT 30
RATED HEAT OUTPUTkW6810121518222430
SEASONAL HEATING ENERGY EFFICIENCY%36,7236,7236,7236,7236,7236,7236,7236,7236,72
ENERGY EFFICIENCY CLASSЕнергиен етикет 6 mrl/kЕнергиен етикет 6 mrl/kЕнергиен етикет 6 mrl/kЕнергиен етикет 6 mrl/kЕнергиен етикет 6 mrl/kЕнергиен етикет 6 mrl/kЕнергиен етикет 6 mrl/kЕнергиен етикет 6 mrl/kЕнергиен етикет 6 mrl/k
USEFUL HEATING POWERkW5,967,949,9311,9214,917,8721,8523,8229,79
EFFICIENCY%99,399,399,399,399,399,399,399,399,3
COST OF AUXILIARY POWER SUPPLYkW0,0060,0060,0060,0060,0060,0060,0060,0060,006
SOUND POWER LEVELdb333333333333333333
DECLARATION OF CONFORMITY Download Download Download Download Download Download Download Download Download
PASSPORT Download Download Download Download Download Download Download Download Download
PARAMETERSMRT 6-30KW
UNITMRT 6, 8, 10, 12MRT 15MRT 22, 30
MAX OUTPUTkW6, 8, 10, 12 kW15 kW22, 30 kW
BOILER SHELL CAPACITYdm38,98,98,9
SUPPLY VOLTAGEV240/400400400
HEIGHTmm700700700
WIDTHmm385385385
DEPTHmm260260260
PARAMETERSMRT 6-30kW
MAX OPERATING PRESSUREMPa0,25
TEST PRESSUREMPa0,40
HEATING AGENT TEMPERATURE CONTROL° C30-90
ROOM TEMPERATURE CONTROL° C5-30
CONNECTOR SIZE VOI 6-30KWG1"
EFFICIENCY%99.30
Feature:

✓ The MRT electric boilers whit three-stage control have Emergency (blocking) thermostat, circulation pump, expansion tank and pressure switch.

Module Т 6-30

Electric module with three-stage control 6-30 T

Three-stage control make proportionately control of the water temperature in the water container according to the difference between the set temperature and the current temperature in the heating place.

Manufactured models Module-T – 6kW, 8kW, 10kW, 12kW, 15kW, 22kW, 30kW

PRODUCT DATAT 6-30KW
UNITT 6T 8T 10T 12T 15T 18T 22T 24T 30
RATED HEAT OUTPUTkW6810121518222430
SEASONAL HEATING ENERGY EFFICIENCY%36,7236,7236,7236,7236,7236,7236,7236,7236,72
ENERGY EFFICIENCY CLASSЕнергиен етикет 6TЕнергиен етикет 8TЕнергиен етикет 10TЕнергиен етикет 12TЕнергиен етикет 15 mrlЕнергиен етикет 15 mrlЕнергиен етикет 22TЕнергиен етикет 22TЕнергиен етикет 30T
USEFUL HEATING POWERkW5,967,949,9311,9214,917,8721,8523,8229,79
EFFICIENCY%99,399,399,399,399,399,399,399,399,3
COST OF AUXILIARY POWER SUPPLYkW0,0060,0060,0060,0060,0060,0060,0060,0060,006
SOUND POWER LEVELdb333333333333333333
DECLARATION OF CONFORMITY Download Download Download Download Download Download Download Download Download
PASSPORT Download Download Download Download Download Download Download Download Download
PARAMETERST 6-30KW
MAX OUTPUTkW6-30kW
BOILER SHELL CAPACITYdm38,9
SUPPLY VOLTAGEV240/400
HEIGHTmm645
WIDTHmm315
DEPTHmm270
PARAMETERST 6-30kW
MAX OPERATING PRESSUREMPa0,25
TEST PRESSUREMPa0,40
HEATING AGENT TEMPERATURE CONTROL° C30-90
ROOM TEMPERATURE CONTROL° C5-30
CONNECTOR SIZE VOI 6-30KWG1"
EFFICIENCY%99.30
Feature:

✓ The electric Module T whit three-stage control have Emergency (blocking) thermostat, circulation pump, expansion tank and pressure switch.

Advantages

Convenient solution for heating

Constant heating is an important element of modern life. These continuous flow electric heaters from the range of Ecotermal with Three-stage control MRT and Module-T satisfies all your needs in the easiest possible way, and extremely comfortably. All you need is power. The boilers are available in different variants with a wide range of heating capacities  from 6 to 90 kW. They are ideal for apartments, single-family houses and offices.

Enjoy great quality

Boilers and modules Ecotermal MRT and Module T. Their installation is extremely convenient – it only needs to be hung on the wall and connected to the mains. Maintenance is also uniquely simplified. Remove a few screws from the front and here are the most important components available. Thus, the working hours of the service technician are minimized.

Smart electronics and high comfort

The use of the device brings real joy with the intuitive control concept. The clear control panel with buttons and graphic display is very convenient to use, and each step is as easy as child’s play.

Recommendations

It is advisable to have a project developed for every specific installation. Installation shall only be made by qualified authorized personnel. Heater installation shall be in conformity with the currently valid regulations, standards and this instruction manual. Heater adjustment and commissioning shall only be made by the vendor’s approved service engineer.