MR 6-30

Electric boiler with relay control MR 6-30

The electric boilers model MR have contains temperature controller. The temperature set-point value can be adjusted between 30°C and 90°C.
Manufactured models MR: – 6kW, 8kW, 10kW, 12kW, 15kW, 22kW, 30kW.
PRODUCT DATAMR 6-30KW
UNITMR 6MR 8MR 10MR 12MR 15MR 18MR 22MR 24MR 30
RATED HEAT OUTPUTkW6810121518222430
SEASONAL HEATING ENERGY EFFICIENCY%36,7236,7236,7236,7236,7236,7236,7236,7236,72
ENERGY EFFICIENCY CLASSЕнергиен етикет 6 mrЕнергиен етикет 8 mrЕнергиен етикет 10 mrЕнергиен етикет 12 mrЕнергиен етикет 15 mrЕнергиен етикет 15 mrЕнергиен етикет 22 mrЕнергиен етикет 22 mrЕнергиен етикет 30 mr
USEFUL HEATING POWERkW5,967,949,9311,9214,917,8721,8523,8229,79
EFFICIENCY%99,399,399,399,399,399,399,399,399,3
COST OF AUXILIARY POWER SUPPLYkW0,0020,0020,0020,0020,0020,0020,0020,0020,002
SOUND POWER LEVELdb343434343434343434
DECLARATION OF CONFORMITY Download Download Download Download Download Download Download Download Download
PASSPORT Download Download Download Download Download Download Download Download Download
PARAMETERSMR 6-30KW
MAX OUTPUTkW6,8,10,121522,30
BOILER SHELL CAPACITYdm38,98,98,9
SUPPLY VOLTAGEV240/400400400
HEIGHTmm700700700
WIDTHmm385385385
DEPTHmm280280280
PARAMETERSMR 6-30kW
MAX OPERATING PRESSUREMPa0,25
TEST PRESSUREMPa0,40
HEATING AGENT TEMPERATURE CONTROL° C30-90
ROOM TEMPERATURE CONTROL° C5-30
CONNECTOR SIZE VOI 6-30KWG1"
EFFICIENCY%99.30
Feature:

✓ The MR electric boilers whit relay control have thermostat -bimetallic, emergency (blocking) thermostat, system control –contactors and pressure switch.

MX 37-60

Electric boiler with relay control MX 37-60

The electric boilers model MX have contains temperature controller. The temperature set-point value can be adjusted between 30°C and 90°C.

Manufactured models MX: – 37kW, 45kW, 52kW, 60kW.

PRODUCT DATAMX 37-60КW
UNITMX 37MX 45MX 52MX 60
RATED HEAT OUTPUTkW37455260
SEASONAL HEATING ENERGY EFFICIENCY%36,7236,7236,7236,72
ENERGY EFFICIENCY CLASSЕнергиен етикет 37 mxlЕнергиен етикет 45 mxlЕнергиен етикет 52 mxlЕнергиен етикет 60 mxl
USEFUL HEATING POWERkW36,7444,6951,6459,58
EFFICIENCY%99,399,399,399,3
COST OF AUXILIARY POWER SUPPLYkW0,0020,0020,0020,002
SOUND POWER LEVELdb34343434
DECLARATION OF CONFORMITY Download Download Download Download
PASSPORT Download Download Download Download
PARAMETERSMX 37-60kW
MAX OUTPUTkW37, 4552, 60
BOILER SHELL CAPACITYdm32626
SUPPLY VOLTAGEV400400
HEIGHTmm780780
WIDTHmm500500
DEPTHmm295295
PARAMETERSMX 37-60kW
MAX OPERATING PRESSUREMPa0,25
TEST PRESSUREMPa0,40
HEATING AGENT TEMPERATURE CONTROL° C30-90
ROOM TEMPERATURE CONTROL° C5-30
Присъединителни размери ВОИ 6-60kWG1"
EFFICIENCY%99.30
Feature:

✓ The MX electric boilers whit relay control have thermostat -bimetallic, emergency (blocking) thermostat, system control –contactors and pressure switch and circulation pump.

Module-K 6-60

Electric module with relay control 6-60K

The electric Module-K have contains temperature controller. The temperature set-point value can be adjusted between 30°C and 90°C.We produce 13 types of electrical modules with relay control so that we can satisfy all your needs in the easiest possible way.

Manufactured models Modul-K – 6kW, 8kW, 10kW, 12kW, 15kW, 18kW, 22kW, 24kW, 30kW, 37kW, 45KW, 52kW, 60kW.

PRODUCT DATAModul-K 6-60KW
UNITK 6K 8K 10K 12K 15K 18K 22K 24K 30K 37K 45K 52K 60
RATED HEAT OUTPUTkW681012151822243037455260
SEASONAL HEATING ENERGY EFFICIENCY%36,7236,7236,7236,7236,7236,7236,7236,7236,7236,7236,7236,7236,72
ENERGY EFFICIENCY CLASSK 30Енергиен етикет 6LK 30Енергиен етикет 8LK 30Енергиен етикет 10LK 30Енергиен етикет 12LK 30Енергиен етикет 15LK 30Енергиен етикет 15LK 30Енергиен етикет 22LK 30Енергиен етикет 22LK 30Енергиен етикет 30LK 30Енергиен етикет 37LK 30Енергиен етикет 45LK 30Енергиен етикет 52LK 30Енергиен етикет 60L
USEFUL HEATING POWERkW5,967,949,9311,9214,917,8721,8523,8229,7936,7444,6951,6459,58
EFFICIENCY%99,399,399,399,399,399,399,399,399,399,399,399,399,3
COST OF AUXILIARY POWER SUPPLYkW0,0020,0020,0020,0020,0020,0020,0020,0020,0020,0020,0020,0020,002
SOUND POWER LEVELdb33333333333333333333333333
DECLARATION OF CONFORMITY Download Download Download Download Download Download Download Download Download Download Download Download Download
PASSPORT Download Download Download Download Download Download Download Download Download Download Download Download Download
PARAMETERSModul М 6-60kW
MAX OUTPUTkW6, 3037, 60
BOILER SHELL CAPACITYdm38,926
SUPPLY VOLTAGEV400400
HEIGHTmm645780
WIDTHmm315500
DEPTHmm280295
PARAMETERSModul М 6-60kW
MAX OPERATING PRESSUREMPa0,25
TEST PRESSUREMPa0,40
HEATING AGENT TEMPERATURE CONTROL° C30-90
ROOM TEMPERATURE CONTROL° C5-30
Присъединителни размери ВОИ 6-60kWG1"
EFFICIENCY%99.30
Feature:

✓ The Module K electric boilers whit relay control have thermostat -bimetallic, emergency (blocking) thermostat, system control –contactors and pressure switch.

Advantages

Convenient solution for heating

Constant heating is an important element of modern life. These continuous flow electric heaters from the range of Ecotermal with Three-stage control MRT and Module-T satisfies all your needs in the easiest possible way, and extremely comfortably. All you need is power. The boilers are available in different variants with a wide range of heating capacities  from 6 to 60 kW. They are ideal for apartments, single-family houses and offices.

Enjoy great quality

Boilers and modules Ecotermal MR, MX and Module K. Their installation is extremely convenient – it only needs to be hung on the wall and connected to the mains. Maintenance is also uniquely simplified. Remove a few screws from the front and here are the most important components available. Thus, the working hours of the service technician are minimized.

Smart electronics and high comfort

The use of the device brings real joy with the intuitive control concept. The clear control panel with buttons and graphic display is very convenient to use, and each step is as easy as child’s play.

Recommendations

It is advisable to have a project developed for every specific installation. Installation shall only be made by qualified authorized personnel. Heater installation shall be in conformity with the currently valid regulations, standards and this instruction manual. Heater adjustment and commissioning shall only be made by the vendor’s approved service engineer.